Help Make Passive Building Mainstream Support PHIUS
Certified Projects Database
up down
No. 1608 Project Tracy Community Housing Status Certified
Lead CPHC Chris West
Builder Estes & Gallup Location Lebanon, , NH
QA/QC Rater Karen Bushey Architecture Planning Maclay Architects Mechanical Systems Designer Engineering Services of Vermont, LLC
Constr. Type Timber Bldg. Function Multifamily Floor Area 26246
Project Type New Construction HERS Index LEED Rating
Energy Star Rating Heating Degree Days Cooling Degree Days
Units 29 Certification Type PHIUS+2015 - PHIUS+ Source Zero Certification Date April 23, 2020
Exterior Wall 2x6 Frame Walls with Cellulose, 4in outboard polyiso, R-36
Floor Slab on grade, 5in XPS, R-25
Roof Outboard Polyiso, R-55
Window Frame
Window Glazing U-0.22
Entrance Door
Ventilation Fresh air ventilation is supplied through a rooftop Daikin energy recovery ventilator that supplies living and bedrooms, and exhausts from bathrooms and kitchens.
Heating System Each apartment has a dedicated Mitsubishi M-series air source heat pump for heating and cooling, with one head in the living area. The apartments have operable awning windows and individual thermostat control of their air source heat pumps for heating and cooling.
Submitter Chris West
Air-tightness 0.044 cfm50/ft2 enclosure
Cooling System
Additional Consultants
Additional Notes