No. 1550 Project Meadows two Status Pre-certified
Lead CPHC Michal Kaleta
Builder Allied Cook Location Hampton Falls , NH
QA/QC Rater Mike Browne Architecture Planning Lassel Architects Mechanical Systems Designer Petersen Engineering
Constr. Type Timber Bldg. Function Multifamily Floor Area 20290
Project Type New Construction HERS Index LEED Rating
Energy Star Rating Heating Degree Days 6946 Cooling Degree Days
Units Certification Type PHIUS+2015 Certification Date
Exterior Wall R 37.754 - Vinyl siding - Zip R 3 (1/2" zip sheathing, 1/2" rigid insulation), all seams taped (WRB + Air tightness) - 1" XPS (R6/in.) - zip sheathing - Densepack Blown-in Fiberglass in 2x8 cavity (Certainteed TrueComfort R31 in 2x8 cav.) - Smart Vapor control layer (INTELLO PLUS/ SIGA MAJREX/ CERTAINTEED MEMBRAIN) - GWB with latex paint
Floor R 23.392 - floor finish (carpet tile or vinyl plank) - 4" concrete - 3" XPS (R6/in.) - STEGO wrap 15 mil. - Compacted gravekl
Roof R 50.121 - asphalt shingle / TPO membrane - 1/2" OSB underlayment, all seams taped - 2" XPS (R6/in.) - 5/8" Zip Sheathing roof deck, all seams taped - 7" Spray Polyurethane foam
Window Frame U = 0.2
Window Glazing U = 0.129 SHGC 0.538
Entrance Door R 3.808 aluminum storefront
Ventilation ERV - ZEHNDER CA 550 one per 4-5 appartments 8 total
Heating System 2 VRF Heat pumps for apartments, 'suitcase' Heat pump for commons spaces concealed in closets ASHP in apartments two groups (one per each VRF), wall mounted cassetes for common spaces. heating and cooling
Submitter Michal Kaleta
Air-tightness 0.038 cfm50/ft2
Cooling System 2 VRF Heat pumps for apartments, 'suitcase' Heat pump for commons spaces concealed in closets ASHP in apartments two groups (one per each VRF), wall mounted cassetes for common spaces. heating and cooling
Additional Consultants
Additional Notes -affordable senior housing -24 dwelling units (max 48 occupants), no dishwashers, recirc. hood, -Central Laundry room (3 Washers; 3 dryers) -Mechanical and Recycling room insulated envelope, but area outside Passive House (zone 2 in model)