Help Make Passive Building Mainstream Support PHIUS
Certified Projects Database
No. 1367 Project 11 West 126th Street Status Pre-certified
Lead CPHC Thomas Moore
Builder Banta Homes Corporation Location New York City , NY
QA/QC Rater Architecture Planning PBDW Architects Mechanical Systems Designer AltieriSeborWieber
Constr. Type Insulated concrete forms Bldg. Function Multifamily Floor Area 9655
Project Type New Construction HERS Index LEED Rating
Energy Star Rating Heating Degree Days 3992 Cooling Degree Days 1482
Units 6 Certification Type PHIUS+2015 Certification Date
Exterior Wall Insulated Concrete Forms made from Expanded Polystyrene, R: 30.0 hr ft2 F/Btu, U: 0.03 Btu/hr ft2 F
Floor 1" XPS under slab and grade beams, R: 5.42 hr ft2 F/Btu, U: 0.16 Btu/hr ft2 F
Roof Expanded Polystyrene on concrete deck with insulated parapet, R: 68.2 hr ft2 F/Btu, U: 0.01 Btu/hr ft2 F
Window Frame SHUCO AWS 70.1 - Fixed & Tilt/Turn, U Frame: 0.19 - 0.21 Btu/hr ft2 F
Window Glazing SHUCO AWS 70.1, U Glass: 0.088 Btu/hr ft2 F, SHGC: 0.38
Entrance Door SHUCO ADS 70.1, U Frame: 0.35 -0.41 Btu/hr ft2 F
Ventilation Energy Recovery Ventilator - Zehnder ComfoAir 200
Heating System Ducted Air Source Heat Pump VRF - AOU18RLFC/ARU18RLFCC
Submitter Thomas Moore
Air-tightness 0.08 CFM/ft2
Cooling System Ducted Air Source Heat Pump VRF - AOU18RLFC/ARU18RLFCC
Additional Consultants The Levy Partnership