No. | 1323 | Project | Christianson PH | Status | Certified |
---|---|---|---|---|---|
Lead CPHC |
Win Swafford Jan Fillinger |
Builder | G. Christianson Construction | Location | Corvallis, OR |
QA/QC Rater | Ryan Shanahan, Earth Advantage | Architecture Planning | Jan Fillinger, Studio-E Architecture | Mechanical Systems Designer | Rodger Housing, Hendrix Heating |
Constr. Type | Timber | Bldg. Function | Single Family | Floor Area | 1935 |
Project Type | New Construction | HERS Index | 0 | LEED Rating | |
Energy Star Rating | 3.0 | Heating Degree Days | 4379 | Cooling Degree Days | 1096 |
Units | 1 | Certification Type | PHIUS+2015 - PHIUS+ Source Zero | Certification Date | August 24, 2017 |
Exterior Wall | (R32.2) HardiPlank siding, 3/4" plywood rainscreen, 2" of Cork insulation, Zipwall sheathing w/ Prosoco fast flash on seams (WRB & air barrier layer), 2x8 framing w/ dense pack fiberglass, 5/8" drywall | ||||
Floor | (R66.4) 16" TJI w/ dense pack fiberglass at 24â€oc, 1 1/8" Edge Gold OSB subfloor, 3/4" Hickory site finished hardwood floor | ||||
Roof | (R103.7) Standing Seam, synthetic roof paper, 5/8†CDX plywood, 1 1/2" air gap, 7/16" OSB, 26" parallel cord trusses w/24" dense pack fiberglass, 7/16" OSB SIGA taped seams (air barrier), 2x6 fire sprinkler furring chase, 5/8 drywall. | ||||
Window Frame | Zola Thermo uPVC, Tilt-Turn, U=0.19 | ||||
Window Glazing | Zola Thermo uPVC U=0.09 | ||||
Entrance Door | ThermaTru Classic Craft American with stained glass, three-point lock system, gasketing all four sides, U=0.26 Back door: Zola Thermo Clad II, Inswing Pair, French Entry door, U=0.15 | ||||
Ventilation | Zehnder Comfo Air 350 Zephyr Kitchen Hood, exhausts to the outdoors with gravity damper | ||||
Heating System | Mitsubishi Minisplit system, one 6kbtu head downstairs, one 6kbtu head upstairs, controlled by Nest thermostats | ||||
Submitter | Win Swafford | ||||
Air-tightness | 0.64 ACH50, 0.032 cfm50/ft2 | ||||
Cooling System | Mitsubishi Minisplit system | ||||
Additional Consultants | Win Swafford, CPHC modeler | ||||
Additional Notes | Energy Trust of Oregon modeled that the home is saving $1,712 per year in energy costs. Includes 8.26KW solar array to be Net Zero. Detached garage |