Certified Projects Database
No. |
1236 |
Project |
Madrona Passive House |
Status |
Certified |
Lead CPHC |
|
Builder |
Hammer and Hand |
Location |
Seattle, WA |
QA/QC Rater |
Skylar Swinford |
Architecture Planning |
SHED Architects |
Mechanical Systems Designer |
Dan Whitmore, Washington State University and Petra Heating |
Constr. Type |
Timber |
Bldg. Function |
Single Family |
Floor Area |
3778 |
Project Type |
New Construction |
HERS Index |
|
LEED Rating |
|
Energy Star Rating |
|
Heating Degree Days |
4720 |
Cooling Degree Days |
174 |
Units |
1 |
Certification Type |
PHIUS+2015
|
Certification Date |
September 13, 2016 |
Exterior Wall |
5/8' GWB, 2x6 with Blown-In Dense Fiberglass, 7/16" Zip Sheathing, 4" Fiberglass-faced Poly-Isocyanurate Insulation, WRB Membrane, 1x4 Douglas Fir Furring, T&G Cedar |
Floor |
2 1/2" Polished Concrete, 5.5" Extruded Polystyrene (EPS), Drainage Matt, 10-Mil Poly, 6" Reinforced Concrete |
Roof |
5/8' GWB, 11 7/8" I-Joist with Blown-In Dense Fiberglass, 5/8" Plywood, 5+" sloped EPS Insulation, 1/2" Protection Board, TPO Roofing |
Window Frame |
Zola ThermoClad Plus |
Window Glazing |
SHGC: 0.53
Ucog: 0.095 BTU/hr.ft2.F |
Entrance Door |
Zola |
Ventilation |
Zehnder Comfoair 550 |
Heating System |
Sanden Heat Pump Water Heater |
Submitter |
Dan Whitmore |
Air-tightness |
0.34 |
Cooling System |
Exterior Shading/Blinds, night-flushing |
Additional Consultants |
|
Additional Notes |
|