Certified Projects Database
No. |
1219 |
Project |
Turner House |
Status |
Certified |
Lead CPHC |
Natalie Leonard
|
Builder |
|
Location |
Hubley, NS |
QA/QC Rater |
Jordan MacDonald |
Architecture Planning |
|
Mechanical Systems Designer |
|
Constr. Type |
|
Bldg. Function |
Single Family |
Floor Area |
2083 |
Project Type |
New Construction |
HERS Index |
|
LEED Rating |
|
Energy Star Rating |
|
Heating Degree Days |
|
Cooling Degree Days |
|
Units |
1 |
Certification Type |
PHIUS+
|
Certification Date |
September 22, 2015 |
Exterior Wall |
2x4 TJI Cellulose 12", Polyiso 3"
|
Floor |
4" Concrete, 10" ESP Type 2
|
Roof |
26-1/2" Cellulose
|
Window Frame |
Accurate Dorwin ADC 325 series, U- 0.17
|
Window Glazing |
AGC Comfort-E, U-0.17
|
Entrance Door |
R-7.14
|
Ventilation |
Paul -Novus F 300, Daikin
|
Heating System |
Dimplex LPC Series Heat pump
|
Submitter |
Mike Anderson |
Air-tightness |
0.49 ACH 50 |
Cooling System |
N/A
|
Additional Consultants |
|
Additional Notes |
|