Certified Projects Database
No. |
1145 |
Project |
98 Green Valley Rd. Williamsburg, KY |
Status |
Certified |
Lead CPHC |
Michael Hughes
|
Builder |
Kentucky Highlands Investment Corporation |
Location |
Williamsburg, KY |
QA/QC Rater |
N/A |
Architecture Planning |
CSC Design Studio |
Mechanical Systems Designer |
|
Constr. Type |
Timber |
Bldg. Function |
Single Family |
Floor Area |
1094 |
Project Type |
New Construction |
HERS Index |
|
LEED Rating |
|
Energy Star Rating |
|
Heating Degree Days |
4434 |
Cooling Degree Days |
1059 |
Units |
1 |
Certification Type |
PHIUS+
|
Certification Date |
December 1, 2012 |
Exterior Wall |
Double 2x4 Stud wall (11" total cavity) filled with blown-in high density fiberglass, taped OSB sheathing, 2" foil faced polyisocyanurate rigid exterior foam with taped joints, fiber cement siding installed as a rainscreen |
Floor |
2x12 joists @ 24" o.c. filled with blown-in high density fiberglass, taped subfloor, 1 1/2" foil faced polyisocyanurate rigid foam with taped joints installed below the joists in a ventilated crawlspace |
Roof |
Raised heel trusses with 18" loose fill cellulose in ventilated attic, taped OSB below the trusses, 3 1/2" service cavity with blown-in high density fiberglass |
Window Frame |
Thermotech Fiberglass, with interior overinsulation, .26 Uf, .015 installation |
Window Glazing |
SHGC: .64, Ucog: .16 |
Entrance Door |
Insulated Fiberglass, Solid, R-value: 5.56 |
Ventilation |
Ultimate Air RecoupAerator 200DX |
Heating System |
9000 BTU Ductless Fujitsu mini split heat pump, and 12,000 BTU ducted Mitsubishi mini split heat pump |
Submitter |
Michael Hughes |
Air-tightness |
.595 ACH50 |
Cooling System |
9000 BTU Ductless Fujitsu mini split heat pump, and 12,000 BTU ducted Mitsubishi mini split heat pump |
Additional Consultants |
Jim Burris |
Additional Notes |
This project is the same as the others except that its floor plan is mirrored compared to the rest. All other aspects are identical. The floor plan has been uploaded for reference. |