Certified Projects Database
No. |
1056 |
Project |
Wallace Homestead |
Status |
Certified |
Lead CPHC |
Jesse Thompson
|
Builder |
Structures DesignBuild |
Location |
Stuart, VA |
QA/QC Rater |
Leo Watkins |
Architecture Planning |
Kaplan Thompson Architects |
Mechanical Systems Designer |
Kaplan Thompson Architects |
Constr. Type |
Mixed timber-masonry |
Bldg. Function |
Single Family |
Floor Area |
3031 |
Project Type |
New Construction |
HERS Index |
|
LEED Rating |
|
Energy Star Rating |
|
Heating Degree Days |
4832 |
Cooling Degree Days |
1052 |
Units |
1 |
Certification Type |
PHIUS+
|
Certification Date |
February 1, 2013 |
Exterior Wall |
Rear foundation wall: 2" EPS, cast concrete, 2" EPS
Front walls: 2x8 cellulose w/ 3.5" EPS nailbase |
Floor |
Cast concrete on 6" EPS |
Roof |
SIP roof: 2x10 SIP
Earth Roof: 4" EPS on cast concrete on EPS LiteDeck 2- 4" on 7" cellulose |
Window Frame |
Makrowin 88G2 Thermally broken clad wood: 0.15 U in BTU |
Window Glazing |
St Gobain Climatop Ultra Laminated SHGC 0.45 U 0.106 BTU |
Entrance Door |
Makrowin Wood Insulated: R-8 |
Ventilation |
Zehnder ComfoUnit ERV 350 & 200 (2) units |
Heating System |
Mitsubishi Mini-split, one outdoor unit, (3) indoor units. |
Submitter |
Jesse Thompson |
Air-tightness |
0.6 projected |
Cooling System |
Mitsubishi Mini-split, one outdoor unit, (3) indoor units. |
Additional Consultants |
Jesper Kreuse, Maine Passive House, John Semmlehack, Manual J, Structural Integrity engineering |
Additional Notes |
|