Help Make Passive Building Mainstream Support PHIUS
Certified Projects Database
up down
No. 1048 Project 3226 S. US Hwy. 25W, Williamsburg, KY Status Certified
Lead CPHC Michael Hughes
Builder Southern Tier Housing Corporation Location Williamsburg, KY
QA/QC Rater N/A- Pre-Program Architecture Planning CSC Design Studio Mechanical Systems Designer
Constr. Type Timber Bldg. Function Single Family Floor Area 1094
Project Type New Construction HERS Index LEED Rating
Energy Star Rating Heating Degree Days 4434 Cooling Degree Days 1059
Units 1 Certification Type PHIUS+ Certification Date December 1, 2012
Exterior Wall Double 2x4 Stud wall (11" total cavity) filled with blown-in high density fiberglass, taped OSB sheathing, 2" foil faced polyisocyanurate rigid exterior foam with taped joints, fiber cement siding installed as a rainscreen
Floor 2x12 joists @ 24" o.c. filled with blown-in high density fiberglass, taped subfloor, 1 1/2" foil faced polyisocyanurate rigid foam with taped joints installed below the joists in a ventilated crawlspace
Roof Raised heel trusses with 23" loose fill cellulose in ventilated attic, taped OSB below the trusses, 3 1/2" service cavity with blown-in high density fiberglass
Window Frame Thermotech Fiberglass, with interior overinsulation, .26 Uf, .015 installation
Window Glazing SHGC: .64, Ucog: .16
Entrance Door Insulated Fiberglass, Solid, R-value: 7.14
Ventilation Ultimate Air RecoupAerator 200DX
Heating System 9000 BTU Ductless Fujitsu mini split heat pump, and 12,000 BTU ducted Mitsubishi mini split heat pump
Submitter Michael Hughes
Air-tightness .58 ACH50
Cooling System 9000 BTU Ductless Fujitsu mini split heat pump, and 12,000 BTU ducted Mitsubishi mini split heat pump
Additional Consultants Jim Burris
Additional Notes