Help Make Passive Building Mainstream Support PHIUS
Certified Projects Database
up down
No. 1042 Project Lankford House Status Certified
Lead CPHC John Semmelhack
Builder Jobes Builders Location Charlottesville, VA
QA/QC Rater N/A- Pre-Program Architecture Planning Giovanna Galfione-Cox Mechanical Systems Designer Albemarle Heating + Air / Think LIttle
Constr. Type Timber Bldg. Function Single Family Floor Area 1713
Project Type New Construction HERS Index 40 LEED Rating
Energy Star Rating 2.0 Heating Degree Days 4000 Cooling Degree Days 1200
Units 1 Certification Type PHIUS+    
Exterior Wall Double-stud wall with "Agribalance" open cell spray foam (R-41)
Floor 12" TJI with dense-pack cellulose over crawlspace (R-45)
Roof 12" TJI with "Agribalance" open cell spray foam and 2" closed cell roof foam (R-64)
Window Frame Serious Windows 725 series
Window Glazing Serious Windows 725 series
Entrance Door Serious Windows 725 series
Ventilation Ultimate Air 200DX
Heating System Mitsubishi multi-split heat pump with two wall-mounted indoor units
Submitter John Semmelhack
Air-tightness 0.42 ACH50
Cooling System Mitsubishi multi-split heat pump with two wall-mounted indoor units
Construction Year
Additional Consultants
Additional Notes

Subscribe to our Newsletters

YouTube Follow us on Twitter We're on Facebook PHIUS Blog

© 2017 Passive House Alliance. All Rights Reserved. HOME | PRIVACY | BLOG | CONTACT US