No. 1029 Project Fairview II Status Certified
Lead CPHC Katrin Klingenberg
Builder Mike Kernagis / Tim Gibbs Location Urbana, IL
QA/QC Rater NA/Pre-Program Architecture Planning E-co lab - Katrin Klingenberg Mechanical Systems Designer E-co lab
Constr. Type Timber Bldg. Function Single Family Floor Area 1242
Project Type New Construction HERS Index LEED Rating
Energy Star Rating Heating Degree Days 6000 Cooling Degree Days 2000
Units 1 Certification Type PHIUS+    
Exterior Wall 12" TJI Custom SIP Panel filled with Optima High Density Blown in Fiberglass. With additional Interior 2x4 Stud Wall also filled with Optima High Density Blown in Fiberglass.
Floor Frost Protected Thickened Edge Slab with 2" Extruded Polystyrene for Perimeter Insulation. Under the slab is 16" of Expanded Polystyrene Insulation
Roof Prefabricated Wood Truss With Vent Channels and an Interior 2x4 Stud Ceiling. Both are filled with a total of 16" Blown in Fiberglass Insulation
Window Frame Thermotech Fiberglass Frames with EPS Insulation
Window Glazing SHGC of .61 for the South and .37 for the North, East, and West Elevations
Entrance Door
Ventilation Ultimate Air - RecoupAerator 200DX
Heating System 9000 Btu/h Mini Split heat pump with 5x500W Electric-Resistance Baseboard Heater as backup in living spaces
Submitter Katrin Klingenberg
Air-tightness .45 ACH50
Cooling System 20 SEER Mini Split heat pump
Construction Year
Additional Consultants
Additional Notes