No. 1016 Project Rue-Evans House Status Certified
Lead CPHC Blake Bilyeu
Builder Bilyeu Homes Inc. Location Salem, OR
QA/QC Rater NA/Pre-program Architecture Planning Blake Bilyeu Mechanical Systems Designer Carl Robins, Lyons Heating & Cooling
Constr. Type Timber Bldg. Function Single Family Floor Area 1567
Project Type New Construction HERS Index 47 LEED Rating
Energy Star Rating Heating Degree Days 5000 Cooling Degree Days 250
Units 1 Certification Type PHIUS+ Certification Date January 1, 2012
Exterior Wall Double Stud wall filled with Dense Pack Cellulose. Exterior EPS exists as thermal break.
Floor 12" Joist filled with Cellulose. Underneath is 1.5" of Rigid EPS.
Roof 24" Truss filled with Cellulose with 2x4" chase below.
Window Frame Serious Materials 725.
Window Glazing Serious Materials 725 tuned by orientation with High Gain on South
Entrance Door ThermaTru
Ventilation UltimateAir RecoupAerator 200DX
Heating System Heat Pump
Submitter Blake Bilyeu
Air-tightness .2 ACH50
Cooling System Heat Pump/NA
Additional Consultants